4MM Spc Marmor Tabulatum

Description:

SPCTabulatum Specification
Color Code 87024
Crassitudo 3.8mm, 4mm, 4.2mm, 5mm, 5.5mm, 6mm
gere Stratum 0.2mm, 0.3mm, 0.5mm
Magnitudo 600mm* 300mm
Superficies Marmor, Leather, Stone


Product Detail

Color Display

Institutionem

Technical Sheet

Product Tags

Structure

SPC-FLOORING-STRUCTURE
36
41
37
42
38
43
39
44
40
45

Singula Imagines

Marble-spc-floor
white-marble-spc-flooring

Specification

SPCTabulatum Specification
Color Code 87024
Crassitudo 3.8mm, 4mm, 4.2mm, 5mm, 5.5mm, 6mm
gere Stratum 0.2mm, 0.3mm, 0.5mm
Magnitudo 600mm* 300mm
Superficies Marmor, Leather, Stone
Core Material Materia virgo C%
Click Ratio Unilin Click, Iacta Lok(I4F)
Specialis curatio V-Groove, Soundproof EVA/IXPE
Ratio institutionem Curabitur tristique

Quomodo mundare et conservare Spc Vinyl?

SPC VINYL Tabulatum magis ac magis populare est cum consumers ob excellentem eius observantiam, et vestigia SPC tabulationis in multis diversis occasionibus videre possumus.Eligendo VINYL Tabulatum ingenium hominis refert, sed scis quomodo tabulatum PVC ponere?Hodie vobiscum sustentationem et sustentationem PVC Tabulatum communicabo.

Una: Propositum purgationis et sustentationis spc areae vinyl
1. amplio specie
Opportune sordes removentur in usu quotidiano generatae, ita ut area elastica suam eximiam speciem et glossam naturalem plene demonstrat.
2. protege areæ
Tabulatum elasticum defenditur ab oeconomis accidentalibus, cornubus cigarette, notis calceamentis, oleo et aqua, etc., et abrasio mechanica in superficie elevatur, ita ut durabilitas ipsius areae plene expediatur, ita ut vita serviat. area vinyl.
3. Commoda cura
Ob strictam superficiei structuram et specialem tractationem areae elasticae, cura cotidiana purgatio et sustentatio potest faciliorem tabulam facere ad vitam servitutis curandam et prorogandam.

Duo: Praecipua lutum procuratio modi ad spc pavimentum
Ut omnes novimus, SPC PVC Tabulatum habet utilitates antibacterial, altae elasticitatis, resistentis et non-lapsi, probationis et humoris probationis, et convenientis constructionis.Scientia et rationabilis purgatio et conservatio non solum nitidum et luculentum solum custodiunt, sed etiam augent ministerium vitae areae.
1. Si pulvis est, particulae vel substantiae in superficie fundi impregnatae sunt, quaeso in tempore pavimentum mundare, ne haec strages ab superficie areae laedatur et molestiam non necessariam moveat.
2. Si pars superficiei areae graviter inquinata est, neutrum gerens uti potes ad eam mundandam, et tum superficiem pavimenti cum panno humido conterito.Filum penicillo vel aliis peniculis acutis ne utaris ad aream terendam ad damnum superficiei vitandum.
3. Cum pingere, menstrua vel medicamenta in solo casu stillis, eas actu alcoholis statim removeas.Si acido vel aliquo valido menstrua uteris, aream tinctam augere vel colorare causare.
4. Cum pannus uteris cum multa umore ad purgandum, sedulo cura stillicidia aquatica e grano horizontali vel parte iunctis intrando, causando partem connectens aperiendi.
V. PENICULUS humido non uteris, cum purgans pavimentum ceratum, ne purgationem admoveat superficiei cerae, causando tabulatum cerae ortum.Paulo humido scopae uti potes ad pulverem in superficie pavimenti purgandum, et locis gravius ​​inquinatis versari ad purgandum.
6. Si oleum pollutio incidit, eam cum neutro agente purgare potes, ut superficies areae mundatur.
Quamvis SPC VINYL pavimentum aliquatenus resistentiae ignis habeat, etiam incendi potest.Ergo, cum SPC tabulato PVC utens, quaeso vitare quasdam res calefactorias ponere directe in superficie pavimenti PVC ne damnum in area.

Tres: pvc pavimento cura puncta attendere
1. Pollutantes devita: Quamvis SPC VINYL pavimentum facile est mundare, vitandum est scelerisque in conclave inducere, ut condicionem, quae purgari et polluere et pavimento laedere non possit.
2. Acribus obiectis et duris fricat fuge: dura et acuta in cubiculum devita, praesertim cum acuta sint metalla in fundo, ne humi trahat ne laedatur area;
3. Fuge immersionem aquae: vitare magnam aquae quantitatem diu in superficie pavimenti commorantis.Si diu solum maceratum est, penetrare sub pavimento potest et facere solum tabescere et adhaesionem amittere.Contaminatio etiam causare potest per tabulatum cerae tutelae humoris in superficie purgamentorum in interiorem areae penetrare et colorare areae causam;
4. Ardere et ardens vitare: Quamvis Aurea Elephantus Tabulatum molle retardat area ignis (Class B1), non significat tabulam ignium non cremandam esse.Cum igitur homines SPC PVC contignatione utantur, non utuntur cigarette butts ardentibus, culicibus gyris, Vive ferramenta et obiecti metalla summus temperatus directe in area ponuntur ne damnum in area;
5. Fuge lucem fortem: fuge lumen fortes directum, radiorum ultraviolacerum devita, et ne decoloratio et defluvium areae.

Magnitudo

A. Spc Tabulatum Plank

spc-flooring-plank

B. Spc Tabulatum Tile

spc-flooring-tile

SPC Tabulatum Backing

IXPE-Backing

IXPE Backing

Plain-EVA-Backing

Patet Eva Backing

Types metam

Carpet-Surface

Superficies tapete

crystal-surface

Crystal Surface

deep-embossed-surface

Altum caelatum Superficiem

Handscraped-spc-flooring

Handscraped Spc Tabulatum

Leather-Surface

Leather Superficies

Light-Embossed

Lux Embossed

Marble-Surface

Marmor Superficies

Real-Wood

Verus Wood

Beveled Edge Genera

V-groove

Micro V-Groove Beveled

V-Groove-Painted

V Groove Painted

What is Difference between the 100% Virgin Spc Tabulatum and Recycled Spc Tabulatum?

0308

Spc Tabulatum IMPERVIUS Quality Test

Unilin Click

detail
Unilin-Click1

Unilin Click 1

Unilin-Click-2

Unilin Click 2

SPC Tabulatum sarcina List

SPC Tabulatum sarcina List
Magnitudo sqm/pc* kgs/sqm PCs / ctn sqm/ctn ctn / grabatum grabatus/20ft sqm/20ft ctns/20ft Onerare pondus / 20ft
910×148*3.8mm 0.13468 7.8 16 2.15488 63ctn/12pallet, 70ctn/12pallet 24 3439.190 1596 27300
910×148*4mm 0.13468 8.2 15 2.02020 63ctn/6pallet, 70ctn/18pallet 24 3309.088 1638 27600
910*148*5mm 0.13468 10.2 12 1.61616 70 24 2715.149 1680 28000
910*148*6mm 0.13468 12.2 10 1.34680 70 24 2262.624 1680 28000
1220*148*4mm 0.18056 8.2 12 2.16672 72ctn/10pallet, 78ctn/10pallet 20 3250.080 1500 27100
1220*148*5mm 0.18056 10.2 10 1.80560 72 20 2600.064 1440 27000
1220*148*6mm 0.18056 12.2 8 1.44448 78 20 2253.390 1560 27900
1220*178*4mm 0.21716 8.2 10 2.17160 75 20 3257.400 1500 27200
1220*178*5mm 0.21716 10.2 8 1.73728 75 20 2605.920 1500 27000
1220*178*6mm 0.21716 12.2 7 1.52012 70ctn/10pallet, 75ctn/10pallet 20 2204.174 1450 27300
600*135*4mm 0.0810 8.2 26 2.10600 72ctn/10pallet, 84ctn/10pallet 20 3285.36 1560 27400
600*300*4mm 0.1800 8.2 12 2.16000 72ctn/6pallet, 78ctn/14pallet 20 3291.84 1524 27400
1500*225*5mm+2mm IXPE 0.3375 10.6 5 1.68750 64 21 2268 1344 24500
1800*225*5mm+1.5mm IXPE 0.4050 10.5 5 2.025 64 18 2332.8 1152 24900
Animadvertit: Quantitas per receptaculum aptari potest secundum exiguum pondus continentis pro diverso portu.

Commodum

SPC-Floor-Anti-scracth-Test

SPC Floor Anti-scrath Test

SPC-Floor-Fireproof-Test

SPC Floor Fireproof Test

SPC-Floor-Waterproof-Test

SPC Floor IMPERVIUS Test

Applications

application-(2)
application-(4)
application-(3)
application-(11)
application-(1)

Blackbutt Spc Tabulatum Project in Australia - 1

1
3
2

Maculosum Gum Spc Tabulatum Project in Australia - 2

9
6
8
5
7
4

SPC Floor Donec Processus

1-Workshop

1 Officina

5-SPC-Health-Board

IV SPC Salutem Board

8-SPC-Click-Macking-Machine

7 SPC Click Macking Machina

11Warehouse

X CELLA

2-SPC-Coextrusion-Machine

2 SPC Machina Coextrusion

6-SPC-Quality-Test

5 SPC Quality Test

9-Foam-Adding-Machine

VIII spuma addit Machina

12-Loading

XI Loading

3-UV-Machine

3 UV Machine

7-SPC-Cutting-Machine

6 SPC Cutting Machine/strong>

10-Laboratory

9 Laboratorium


  • Previous:
  • Deinde:

  • about17A. Iacta Click Spc Tabulatum instruitur

     

    about17B. Unilin Click Spc Tabulatum instruitur

     

    about17SPC TABULATUM INSTALLATION RATIONE

     

    1. Primum constitue quomodo velis tabulatum currere.De more pro trabibus productis, tabulatum longitudinis cella decurrit.Exceptio sit, cum omnis sit amet.

    2. Ad tabulam angustam inversas vel breves tabulas longitudinum prope muros/ portas vitandas, Gravis est aliquid praemeditari facere.Utens latitudinem cubiculi, computa quot tabulae plenae aptabunt in aream et quantum spatium restat, quod opus erit ex tabulis partialibus tegi.Reliquum spatium divide per duos ad latitudinem tignorum partialium computando.Idem per longitudinem.

    3. Nota quod primus ordo asserum in latitudine non indiget, linguam vacuam abscindere oportebit, ut acies munda, solida versus parietem.

    4. 8mm dilatatio hiatus a pariete in institutione servandus est.Hoc spatium permittet naturalem expansionem hiatus et contractionem asserum.

    5. Tabulae a dextra ad sinistram instituendae.In summo angulo dextro cubiculi primam tabulam pone primo loco, ut et caput et latus commissurae striatae exponantur.

    6. Secundam tabulam in primo ordine anglicans linguam lateralem brevem instrue in longam lateralem sulcus primae tabulae.

    7. Ad secundum ordinem incipiendum, tabulam secandam saltem 152,4mm breviorem quam primo assere inserendo linguam longam lateralem in rimam trabis in primo versu.

    8. Instrue secundam tabulam in secundo ordine inserendo linguam lateralem brevem in antea primum tabulam longam lateralem sulcus inauguratam.

    9. Conlineare tabulam sic transversam linguam brevem tenerum in primo versu labrum sulcus trabis collocatur.

    10. Leni vi utens et ad 20-30 gradum angulum, linguam brevem lateralem in rimam dilatationis asseris impellens, per longam partem commissurae labens.Tabulam ad ius eius modice levare debes ut actionem "labentium" concedat.

    11. Reliquae tabulae in conclavi eadem arte institui possunt.Lacunae expansionis inquisitae fac contra omnes partes verticales fixas (sicut muri, portae, scrinia etc).

    12. Tabulae utiliter cultro facile secari possunt, sicut tabulae cacumen signant et in duas tabulam disrumpunt.

    about17Spc Tabulatum institutionem design

    installation

    Proprium Test Specification et Exitus
    Moles (in pollices) 6×36;6×48;7×48;8×48;9×48;12×24;12×48;12×36;18×36
    Crassitudo 3.8mm, 4.0mm, 4.5mm, 5.0mm, 5.5mm, 6.0mm
    Affectum / Backing 1.5mm vel 2.0mm IXPE et EVA
    quadratum ASTM F2055 - Passes - 0.010 in. max
    Magnitudo et tolerantia ASTM F2055 - Transit - +0.016 in per linearibus peditibus
    Crassitudo ASTM F386 - Passer - Nominal +0.005 in.
    Flexibilitas ASTM F137 - Transit - ≤1.0 in., non rimas vel frangit
    Dimensional Stability ASTM F2199 - Transit - ≤ 0.024 in. per lineari
    Gravis Metal Praesentia / Absentia EN 71-3 C — Meets Spec.(Plumbum, Antimonium, Arsenicum, Barium, Cadmium, Chromium, Mercurium et Selenium).
    Fumus Generationis Resistentia EN ISO 9239-1 (Critical Flux) Proventus 9.1
    Fumus Generationis Resistentia, Non Flaminge Modus EN ISO
    Flammability ASTM E648- Classis 1 Rating
    RELICTUM Indentation ASTM F1914 - Transit - Mediocris minus quam VIII%
    Static Lond Low ASTM-F-970 Transit 1000psi
    Requisita pro gere Group pr EN 660-1 Crassitudo Damnum 0.30
    Resistentia labi ASTM D2047 - Transit -> 0.6 Infectum, 0.6 Siccum
    Resistentia ad lucem ASTM F1515 - Transit - E ≤ 8
    Repugnantia æstus ASTM F1514 - Transit - E ≤ 8
    Electrical MORES (ESD) EN 1815: 1997 2,0 kV in 23 C+1 C . probatum
    Underfloor Heating Apta institutioni super sub pavimento calefactionis.
    Inurere postquam Patefacio ut æstus EN 434 < 2mm pass
    Vinyl Content REDIVIVUS XL circiter%
    Recyclability Potest REDIVIVUS
    Product Warranty X ANNUS Commercial & XV-Year Residential
    Floorscore Certified Certificatorium dummodo Request
    Epistulam tuam hic scribe et mitte nobis

    RELATED PRODUCTS